Key Equipment Highlights

  • Standard: ISO 13485 & CE Medical Grade Certified
  • Supply: Direct Dispatch Across India with Safety Packaging
  • Support: Includes Biomedical Installation & Warranty Support

Full Technical Specifications & Clinical Application

FEATURES

KVO Status

  • Auto progress KVO mode.
  • Keep the patient's veins open.

Audible Alarm

  • Sensitive alarm reminder to ensure injection safety in real time.

Pressure Monitoring

  • Overvoltage protection.
  • The blocking pressure can be detected precisely and sensitively by a pressure sensor installed in the push handle.

One-Key Operation

  • Fulfill conversion between ml/min and ml/h with one key.

Data Storage

  • Data storage function, convenient for medical staff to review historical alarm information.

Safe and Reliable

  • System self-test is completed as turning on, which ensures safe work.
  • Real-time built-in monitoring makes operation more secure and reliable.

SPECIFICATION

  • Show: 3 inch monochrome LCD display
  • Infusion speed: 1 ml/h - 1200 ml/h, can be incremented or decreased by 0.1 ml/h
  • Infusion volume accuracy: ±5% (ordinary infusion set)
  • Infusion volume preset: 0.1 ml - 9999.9 ml, can be incremented or decreased by 0.1 ml/h
  • Blocking pressure: High: 110 kPa; Medium: 80 kPa; Bottom: 40 kPa
  • KVO: 1 ml/h - 5 ml/h, can be incremented or decreased by 0.1 ml/h
  • Voltage: Power supply voltage AC 100~240V AC, power frequency 50/60Hz; battery input 9.5V-1
  • Power consumption: Not more than 35VA
  • Built-in battery working time: D.C. 11.1V, no less than 2000mA, no less than 12 hours
  • Dimensions: 90 × 205 × 151
  • Weight: 1.5 kg
  • Safety classification: Class I, type BF general equipment with internal power supply
  • Waterproof level: IPX1

WORKING ENVIRONMENT

  • Ambient temperature: 10°C~30°C
  • Relative humidity: 30%~75%
  • Atmospheric pressure: 860 hPa~1060 hPa
  • The infusion pump should work in an environment where there is no strong shock and vibration.
  • Water and other fluids cannot invade the inside of the device.
  • There should be no corrosive gas around.

STORAGE ENVIRONMENT

  • The applied infusion pump should be kept in a room with relative humidity of no more than 93% (no condensation).
  • Non-corrosive and good ventilation.
  • Indoor temperature conditions are: -20°C~+55°C.
Catalog Recommendations

Related Medical Equipment

SANVIORA LIFECARE DUAL PROB WARMER - KB02
Baby Warmer

SANVIORA LIFECARE DUAL PROB WARMER - KB02

SILENT FEATURES EASY TO USEAs technology advanced, we have kept the warmer simple & easy to use...

View Technical Details
SANVIORA LIFECARE SINGLE PROB WARMER - KB01
Baby Warmer

SANVIORA LIFECARE SINGLE PROB WARMER - KB01

SILENT FEATURES EASY TO USEAs technology advanced, we have kept the warmer simple...

View Technical Details
ANAESTHESIA TROLLEY - SLC-A137
Anaesthesia Trolley

ANAESTHESIA TROLLEY - SLC-A137

SPECIFICATION• Two gases Rotameter Oxygen & Nitrous-oxide.• Oxygen flowmeter...

View Technical Details