SANVIORA LIFECARE VENTILATOR - LTV-950
Category: Ventilator
| SKU: LTV-950
Ventilator
Quality Verified
SANVIORA LIFECARE VENTILATOR - LTV-950
Key Equipment Highlights
- Standard: ISO 13485 & CE Medical Grade Certified
- Supply: Direct Dispatch Across India with Safety Packaging
- Support: Includes Biomedical Installation & Warranty Support
Full Technical Specifications & Clinical Application
SPECIFICATIONS
PHYSICAL SPECIFICATIONS WITH BOOTS (APPROX.)
- Weight: 13.4 lbs. (6.1 kg)
- Height: 3 inches (8 cm)
- Width: 10 inches (23 cm)
- Depth: 12 inches (30 cm)
CONTROLS
- Power: On/Standby
- Ventilation Modes: Control, Assist/Control, SIMV, CPAP, NPPV
- Breath Types: Volume Control, Pressure Control, Pressure Support, Spontaneous
- Breath Rate: 0–80 breaths per minute
- Tidal Volume: 50–2000 ml
- Inspiration Time: 0.3–9.9 seconds (100 lpm)
- PC/PS/Spontaneous Flow: 160 lpm
- Pressure Control: 1–99 cmH2O
- Pressure Support: Off, 1–60 cmH2O
- Sensitivity: Off, 1–9 lpm
- Bias Flow: 10 lpm during exhalation
- PEEP/CPAP: 0–20 cmH2O
- Control Lock: Easy or Hard unlock methods
- Manual Breath: 1× current settings
VARIABLE ALARMS
- Apnea Interval: 10–60 seconds
- High Pressure Limit: 5–100 cmH2O
- Low Peak Pressure: Off, 1–60 cmH2O
- Low Minute Volume: Off, 0.1–99 liters
- Alarm Volume: 60–85 dBA at 1 meter
- Alarm Silence/Reset: 60 seconds
- Ventilator Inoperative: Red LED, audible alarm
- High Rate Alarm: Off, 5–80 bpm
- High PEEP Alarm: Off, 3–40 cmH2O
MONITORS AND INDICATORS
- Peak Inspiratory Pressure: 0–120 cmH2O
- Mean Airway Pressure: 0–99 cmH2O
- PEEP: 0–99 cmH2O
- Total Breath Rate: 0–250 bpm
- Airway Pressure Display: -10–108 cmH2O
- Exhaled Tidal Volume: 0–4000 ml
- Total Minute Volume: 0–99.9 liters
- IERatio: 99:1–1:99
- Calculated Peak Flow: 10–100 lpm
- Patient Effort: Green LED
OPTIONAL ACCESSORIES
- LTM Graphics Monitor Package – P/N 17650-001
- Universal Power Supply – P/N 14546-001
- Floor Stand – P/N 10611
- Utility Basket – P/N 11450
- Long Crossbar – P/N 11452
- Circuit Support Arm – P/N 11501
- Humidifier Pole – P/N 11453
- Oxygen Canister Ring Set – P/N 11455
- UPS Mounting Bracket – P/N 15009-001
ENVIRONMENTAL SPECIFICATIONS
- Operating Temperature: 5°–40°C (40°–104°F)
- Storage Temperature: -20°–60°C (-4°–140°F)
- Operating Humidity: 15%–95% relative
- Storage Humidity: 10%–95% relative
- Shock Compliance: MIL-STD-810E
- Vibration Compliance: MIL-STD-810E
EXTENDED FEATURES
- Apnea Back-up Ventilation
- Pressure Control and Pressure Support Variable Rise
- Time Pressure Control and Pressure Support Variable Flow Termination Criteria
- Pressure Support Variable Time Termination
- Leak Compensation
POWER SPECIFICATIONS
- 11–15 VDC
- 90–250 VAC
- 47–63 Hz
POWER SPECIFICATIONS
- ETC, cETL Listed
- ISO 13485 Registration
- IEC 601-2-12
- BSI Registered FM 75092
FIXED ALARMS
- Disconnect/Sense Line
- Low & Lost External Power
- Low & Empty Internal Battery
- High & Low Oxygen Inlet Pressure
Catalog Recommendations
Related Medical Equipment
Baby Warmer
SANVIORA LIFECARE DUAL PROB WARMER - KB02
SILENT FEATURES EASY TO USEAs technology advanced, we have kept the warmer simple & easy to use...
View Technical Details
Baby Warmer
SANVIORA LIFECARE SINGLE PROB WARMER - KB01
SILENT FEATURES EASY TO USEAs technology advanced, we have kept the warmer simple...
View Technical Details
Anaesthesia Trolley
ANAESTHESIA TROLLEY - SLC-A137
SPECIFICATION• Two gases Rotameter Oxygen & Nitrous-oxide.• Oxygen flowmeter...
View Technical Details