SANVIORA LIFECARE PATIENT MONITOR - SLC-S90
Category: Patient Monitor
| SKU: SLC-S90
Patient Monitor
Quality Verified
SANVIORA LIFECARE PATIENT MONITOR - SLC-S90
Key Equipment Highlights
- Standard: ISO 13485 & CE Medical Grade Certified
- Supply: Direct Dispatch Across India with Safety Packaging
- Support: Includes Biomedical Installation & Warranty Support
Full Technical Specifications & Clinical Application
Product characteristics
- Multi-language operation: Chinese, English, Spanish, French, German, Turkish, Russian and other languages.
- Fanless design, quiet and energy-saving, reducing cross-infection.
- Various interface available, such as respiratory oxygenation chart, large character interface, other bed observation, easy for users to observe.
- Maximum simultaneous display up to 8 waveforms.
- Conductive ECG same screen display, ECG waveform cascade display.
- Blood oxygen digital filtering technology in SpO2 measurement, anti-motion interference, anti-environmental light interference, superior in weak perfusion measurement.
- Non-invasive blood pressure measurement: manual, continuous, interval measurement optional, 1000 groups of blood pressure data storage.
- 71 alarm event review for all parameters.
- Drug concentration calculation and titration table function.
- Support networking to realize the central monitoring system.
- Resistant to high-frequency electrosurgery and protected against defibrillation effects. (Requires specified ECG cable)
Electrocardiogram (ECG)
- Heart rate value detection range: 15~300 bpm
- Bandwidth: 0.05 Hz~150 Hz
- Precision: 1% or 1 bpm, whichever is the largest absolute value
- Lead selection: GND, standard I, II, III, aVR, aVL, aVF, V
- Resolution: 1 bpm
- Scanning speed: 12.5 mm/s, 25 mm/s, 50 mm/s
- Gain selection: X0.25, X0.5, X1, X2
Pulse rate (PR)
- Measuring range: 30 bpm~240 bpm
- Precision: ±2% (70~100%)
- Pulse rate alarm limit setting range: 30 bpm~240 bpm
- Alarm limit continuously adjustable, upper limit is larger than the lower limit
- Alarm error: -1 bpm
Blood oxygen (SpO2)
- Measuring range: 40~100%
- Resolution: 1%
- Accuracy: 2% (70~100%), not defined below 70%
Respiration (RESP)
- Display: waveforms, values
- Measurement method: thoracic impedance type
- Measuring range of respiration rate: 0~120 rpm
- Resolution: 1 rpm
- Accuracy: the greater of 2% or 2 rpm
Non-invasive blood pressure (NIBP)
- Working mode: manual, automatic, continuous
- Measurement method: Intelligent open inverse oscillation method
- Measuring range: 20~270 mmHg
- Tolerance range: 5 mmHg
- Measurement record: 1000 blood pressure events
Body temperature (TEMP)
- Measuring range: 0.0°C~50.0°C (32°F~122°F)
- Measuring channel: dual channel
- Resolution: 0.1°C
- Precision: 0.2°C error between 25°C and 45°C
- Dual Channels
CO₂
- Mode: Main stream/side stream
- Range: 0~150 mmHg
- Accuracy: ±2 mmHg (0~76 mmHg), ±5% (77~150 mmHg), ±8% (101~150 mmHg)
- Respiratory Rate Range: 0~150 RPM
- Accuracy: ±2 RPM
- Sampling Flow: 50 mL/min
Catalog Recommendations
Related Medical Equipment
Baby Warmer
SANVIORA LIFECARE DUAL PROB WARMER - KB02
SILENT FEATURES EASY TO USEAs technology advanced, we have kept the warmer simple & easy to use...
View Technical Details
Baby Warmer
SANVIORA LIFECARE SINGLE PROB WARMER - KB01
SILENT FEATURES EASY TO USEAs technology advanced, we have kept the warmer simple...
View Technical Details
Anaesthesia Trolley
ANAESTHESIA TROLLEY - SLC-A137
SPECIFICATION• Two gases Rotameter Oxygen & Nitrous-oxide.• Oxygen flowmeter...
View Technical Details