MULTIPARA PATIENT MONITOR - CMS 6000 Certified
Gallery 1
Patient Monitor Quality Verified

MULTIPARA PATIENT MONITOR - CMS 6000

Key Equipment Highlights

  • Standard: ISO 13485 & CE Medical Grade Certified
  • Supply: Direct Dispatch Across India with Safety Packaging
  • Support: Includes Biomedical Installation & Warranty Support

Full Technical Specifications & Clinical Application

The monitor has abundant monitoring function and is used monitoring of adult, pediatric and neonate. User may select different parameter according to different requirements. It displays real-time data and waveform by 8" TFT color LCD, and up to 8-channel waveform and almonitoring parameters can be displayed simultaneously. 48mm thermal printer is optional.

ECG

5 lead or 12 lead selectable

Input: 5 lead; RA, LT, RL, LL, V or R, L, N, F, C
Lead Selection: I, II, III, aVR, aVL, aVF, Vx, CAL
Gain Selection: x25, x0.5 x1, x2, auto
Sweep Speed Selection: 12.5mm/s, 25mm/s, 50mm/s
Accuracy: +1bpm or +1% whichever is greater
Protection: Withstand 4000V AC/50Hz voltage in isolation against electrosurgical and defibrillation
Calibration signal: 1mV+5% Operation modes, Diagnostic, Monitor, Surgery
Heart rate range: Adult; 15-3000bpm; Pediatric/Neonatal: 15-350bpm
Measurement range: -2.0mV to 2.0mV
ST Detection: YES, Arrhythmia analysis
YES Alarm: YES, audible and visual alarm, alarm events recallable.

NIBP

Method: Oscillometry
Mode: Manual/Auto/STAT
Measurement Range: Adult 10-270mmHg
Measurement Type: Systolic, Diastolic, Mean
Resolution: 1mmHg
NIBP Accuracy: Mean +5mmHg, SD +mmHg
Alarm: SYS/DIA/MEAN

RESPIRATION

Method: RA-LL Impedance
Measurement range: Adult: 0-120rpm, Paediatric/Neonatal 0-150rpm
Apnea Alarm: YES

SpO2

Measurement range: 0%-100%
Accuracy: +2% (70%-100%); 0%-69% unspecified.
Alarm range: 0-100%

PULSE RATE

Measurement range: 10-270
Resolution: 1bpm
Accuracy: +2bpm or +2%

TEMPERATURE

Resolution: 0.2 OC
Channel: Dual-channel
Measurement range: 0-50 OC

DIMENSION

319 mm(L) x 161 mm(W) x 269 mm(h)

Weight: 3.6 Kg

Catalog Recommendations

Related Medical Equipment

SANVIORA LIFECARE DUAL PROB WARMER - KB02
Baby Warmer

SANVIORA LIFECARE DUAL PROB WARMER - KB02

SILENT FEATURES EASY TO USEAs technology advanced, we have kept the warmer simple & easy to use...

View Technical Details
SANVIORA LIFECARE SINGLE PROB WARMER - KB01
Baby Warmer

SANVIORA LIFECARE SINGLE PROB WARMER - KB01

SILENT FEATURES EASY TO USEAs technology advanced, we have kept the warmer simple...

View Technical Details
ANAESTHESIA TROLLEY - SLC-A137
Anaesthesia Trolley

ANAESTHESIA TROLLEY - SLC-A137

SPECIFICATION• Two gases Rotameter Oxygen & Nitrous-oxide.• Oxygen flowmeter...